Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Increased Mortality Following Periprosthetic Joint Infection after Total Hip Arthroplasty:A Microbiologically Verified Nationwide Cohort of 1,611 PJI Revisions

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Publication Date:
      2026
    • Collection:
      Aarhus University: Research
    • Abstract:
      Background Periprosthetic Joint Infection (PJI) following total hip arthroplasty (THA) is a serious complication with potential implications for patient mortality. We evaluated mortality related to PJI revisions compared to major aseptic revisions using a microbiologically verified, population-based, nationwide cohort. Methods We utilized data from the Danish Hip Arthroplasty Register and the Danish Microbiology Database. We included patients who underwent PJI revisions between January 1, 2010, and November 9, 2023, and compared them with patients undergoing major aseptic revisions in the same period. The follow-up period was until April 4, 2024. We calculated mortality using Kaplan-Meier methodology. To balance measured confounding, we used the inverse probability of treatment weighting (IPTW) method to calculate adjusted hazard ratios with 95% confidence intervals (CI) comparing PJI and aseptic revisions in terms of mortality. Confounders included in the weighting were age, sex, weight, Charlson Comorbidity Index (CCI), and marital status. We identified 1,611 PJI revisions and 2,586 major aseptic revisions following primary THA. The mean follow-up time was 6.8 years for PJI revisions and 7.7 years for aseptic revisions. The PJI cohort had a higher proportion of men, were slightly younger, and had a greater prevalence of obesity and comorbidity measured with CCI. Results The PJI cohort had a crude mortality rate of 5.3 deaths per 100 person-years, and the major aseptic revision cohort had a crude mortality rate of 4.4 deaths per 100 person-years. The adjusted Kaplan-Meier 10-year cumulative mortality was 43.9% (CI: 40.5 to 47.1) for PJI and 34.9% (CI: 32.6 to 37.1) for aseptic revisions. Cox proportional hazards analysis revealed an adjusted hazard ratio of 1.33 (CI: 1.20 to 1.48, P < 0.001) for PJI-associated mortality. Conclusion A PJI following THA is associated with a significantly higher mortality risk compared to major aseptic revisions. ; Background Periprosthetic joint infection (PJI) following total ...
    • ISSN:
      0883-5403
      1532-8406
    • Relation:
      info:eu-repo/semantics/altIdentifier/pmid/40484055; info:eu-repo/semantics/altIdentifier/pissn/0883-5403; info:eu-repo/semantics/altIdentifier/eissn/1532-8406; info:eu-repo/semantics/reference/pmid/40480329
    • Accession Number:
      10.1016/j.arth.2025.06.011
    • Online Access:
      https://pure.au.dk/portal/en/publications/3a7604cd-4b52-4fa5-a35b-d0dba9f2b491
      https://doi.org/10.1016/j.arth.2025.06.011
      https://www.scopus.com/pages/publications/105009689110
    • Rights:
      info:eu-repo/semantics/openAccess ; http://creativecommons.org/licenses/by/4.0/
    • Accession Number:
      edsbas.2F90E30F