Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Intraoperative electromyographic monitoring in children using a novel pediatric sensor.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Abstract:
      Background: Train‑of‑four (TOF) monitoring is essential in optimizing perioperative outcomes as a means to assess the depth of neuromuscular blockade and confirm recovery following the administration of neuromuscular blocking agents (NMBAs). Quantitative TOF monitoring has been limited in infants and children primarily due to lack of effective equipment. The current study evaluates a novel electromyography (EMG)‑based TOF monitor with a recently developed pediatric‑sized self‑adhesive sensor in infants and children. Methods: Consented pediatric patients undergoing inpatient surgery requiring the administration of NMBAs were enrolled. The EMG electrode was placed along the ulnar nerve on the volar aspect of the distal forearm. The muscle action potentials from the adductor pollicis muscle were recorded throughout surgery at 20‑second intervals. Data from the monitor’s built‑in memory card were later retrieved and analyzed. Results: The final study cohort included 51 patients who ranged in age from 0.2 to 7.9 years and in weight from 4.2 to 36.0 kilograms. Thirty patients weighed less than 15 kgs. Supramaximal stimulus current intensity (mA) at a pulse width of 200 µsec was 30 mA in 8%; 40 mA in 29%; 50 mA in 16%; and 60 mA in 20% of the patients. Supramaximal stimulus current intensity (mA) at a pulse width of 300 µsec was 50 mA in 4%; 60 mA in 24%. The muscle action potential baseline amplitude was 8.7 ± 3.3 mV and recovered to 7.2 ± 3.7 mV after antagonism of neuromuscular blockade. The average baseline TOF ratio was 100 ± 3% and recovered to 98 ± 7% after antagonism of neuromuscular blockade. No technical issues were noted with application of the sensor or subsequent use of the monitor. Conclusion: Neuromuscular monitoring can be performed intraoperatively in pediatric patients who are less than 8 years of age using a novel commercially available EMG‑based monitor with a recently developed pediatric sensor. The novel sensor allows use of an EMG‑based monitor in infants and children in whom acceleromyography or subjective (visual) observation of the TOF response may not be feasible. Automatic detection of neuromuscular stimulating parameters (supramaximal current intensity level, baseline amplitude of the muscle action potential) was feasible in pediatric patients of all sizes including those weighing less than 15 kilograms or when there was limited access to the extremity being monitored. [ABSTRACT FROM AUTHOR]
    • Abstract:
      Copyright of Saudi Journal of Anaesthesia is the property of Wolters Kluwer India Pvt Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)