Comparison between enzyme-linked immunosorbent assay and indirect immunofluorescence for detection of antineutrophil cytoplasmic antibodies.

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Source:
      Publisher: Instituto de Ensino e Pesquisa Albert Einstein Country of Publication: Brazil NLM ID: 101281800 Publication Model: eCollection Cited Medium: Internet ISSN: 2317-6385 (Electronic) Linking ISSN: 16794508 NLM ISO Abbreviation: Einstein (Sao Paulo) Subsets: MEDLINE
    • Publication Information:
      Original Publication: São Paulo, SP : Instituto de Ensino e Pesquisa Albert Einstein
    • Subject Terms:
    • Abstract:
      Objective: To evaluate the performance of enzyme-linked immunosorbent assay and indirect immunofluorescence methods for the detection of antineutrophil cytoplasmic antibodies in a routine clinical laboratory setting.
      Methods: A total of 227 samples were tested by indirect immunofluorescence and enzyme-linked immunosorbent assay with antigen specificity for antiproteinase 3 and antimyeloperoxidase. The proportions of positive samples were compared by McNemar hypotheses and agreement was described by Cohen's Kappa coefficient.
      Results: The agreement of the tests was 96.5%, and the Kappa coefficient obtained was 0.70 (95%CI: 0.50-0.90; p<0.001). Considering indirect immunofluorescence as the gold standard, the sensitivity of the enzyme-linked immunosorbent assay was 0.62 and the specificity was 0.99, with diagnostic accuracy in 96% of cases. Some samples were negative in enzyme-linked immunosorbent assay and positive in indirect immunofluorescence. This situation occurred in all immunofluorescence patterns, but particularly in atypical patterns. Two samples with antiproteinase 3 positivity were considered negative in indirect immunofluorescence.
      Conclusion: The enzyme-linked immunosorbent assay had high specificity but lower sensitivity. The performance of indirect immunofluorescence increases diagnostic sensitivity, while the search for antiproteinase 3 by enzyme-linked immunosorbent assay may also add diagnostic power.
    • References:
      Front Immunol. 2018 Apr 09;9:680. (PMID: 29686675)
      Nat Rev Rheumatol. 2014 Aug;10(8):494-501. (PMID: 24890776)
      Ann Rheum Dis. 2016 Apr;76(4):647-653. (PMID: 27481830)
      J Clin Pathol. 1999 Sep;52(9):670-6. (PMID: 10655988)
      Semin Immunopathol. 2014 Jul;36(4):461-78. (PMID: 25056155)
      Clin Rheumatol. 2018 Apr;37(4):875-884. (PMID: 29525845)
      Kidney Int. 2000 Mar;57(3):846-62. (PMID: 10720938)
      Clin Exp Immunol. 1995 Mar;99(3):486-92. (PMID: 7882573)
      Nat Rev Rheumatol. 2017 Nov;13(11):683-692. (PMID: 28905856)
      N Engl J Med. 1988 Jun 23;318(25):1651-7. (PMID: 2453802)
      Blood. 1989 Nov 1;74(6):1888-93. (PMID: 2679910)
      Am J Clin Pathol. 1995 Dec;104(6):667-72. (PMID: 8526211)
      Clin Exp Immunol. 1994 Jun;96(3):458-65. (PMID: 7516271)
      Clin Rev Allergy Immunol. 2012 Dec;43(3):211-9. (PMID: 22669754)
      Rev Hosp Clin Fac Med Sao Paulo. 1995 Mar-Apr;50(2):101-6. (PMID: 7569596)
    • Accession Number:
      0 (Antibodies, Antineutrophil Cytoplasmic)
    • Publication Date:
      Date Created: 20200130 Date Completed: 20200323 Latest Revision: 20200323
    • Publication Date:
      20250114
    • Accession Number:
      PMC6980292
    • Accession Number:
      10.31744/einstein_journal/2020AO5132
    • Accession Number:
      31994608