Item request has been placed!
×
Item request cannot be made.
×

Processing Request
Validation of the European visual field standards for driving: A driving simulator-based study.
Item request has been placed!
×
Item request cannot be made.
×

Processing Request
- Additional Information
- Source:
Publisher: Wiley-Blackwell Country of Publication: England NLM ID: 101468102 Publication Model: Print-Electronic Cited Medium: Internet ISSN: 1755-3768 (Electronic) Linking ISSN: 1755375X NLM ISO Abbreviation: Acta Ophthalmol Subsets: MEDLINE
- Publication Information:
Publication: Oxford, UK : Wiley-Blackwell
Original Publication: Oxford, UK ; Malden, MA : Blackwell Munksgaard
- Subject Terms:
- Abstract:
Purpose: To determine whether we could establish evidence-based pass/fail criteria for perimetry in the context of the European visual field standards for driving.
Methods: This two-centre, cross-sectional study included participants with binocular visual field loss that had led to revocation of a group-1 driving licence. The participants underwent cognitive and binocular visual testing, including the European Driving Test (EDT), a perimetry algorithm that adheres to the European visual field standards. We used a high-fidelity driving simulator to compare the driving ability of these participants with healthy controls. Two driving instructors classified each driving test as passed or failed. Receiver operating characteristic (ROC) analysis and area under the curve (AUC) determined the ability of perimetry to discriminate between passed and failed driving tests.
Results: The study included 70 participants with visual field loss and 37 controls. A non-significantly higher proportion of controls passed the driving test (75% vs. 63%; p = 0.22). In ROC analysis, contrast sensitivity performed best (AUC of 0.73), followed by NEI VFQ-25 (AUC of 0.64). Peripheral visual field (AUC of 0.56) and central visual field (AUC of 0.47) performed weaker. Combining the central and peripheral visual field, and their interaction, increased AUC to 0.63.
Conclusion: Perimetry was a poor predictor of simulator-based driving test result, and we could not establish appropriate pass/fail criteria for the European visual field standards. Because perimetry is not an accurate diagnostic tool for fitness to drive, a practical driving assessment should be performed in case of doubt.
(© 2024 WAY AS and The Author(s). Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation.)
- References:
Acta Ophthalmol. 2021 Jun;99(4):e555-e561. (PMID: 32996716)
J Thorac Oncol. 2010 Sep;5(9):1315-6. (PMID: 20736804)
Optom Vis Sci. 2005 Nov;82(11):970-5. (PMID: 16317373)
Br Ir Orthopt J. 2019 Apr 16;15(1):53-63. (PMID: 32999975)
Acta Ophthalmol. 2025 Mar;103(2):222-231. (PMID: 39428625)
Lancet Glob Health. 2021 Oct;9(10):e1411-e1422. (PMID: 34411516)
Acta Ophthalmol. 2018 Sep;96(6):623-630. (PMID: 30246292)
Acta Ophthalmol. 2022 Mar;100(2):e339-e367. (PMID: 34309227)
BMJ Open Ophthalmol. 2022 Feb 23;7(1):e000904. (PMID: 35295687)
BMJ Open. 2023 Aug 11;13(8):e065210. (PMID: 37567751)
Transl Vis Sci Technol. 2022 Mar 2;11(3):20. (PMID: 35297979)
Acta Ophthalmol. 2022 Mar;100(2):218-224. (PMID: 33529454)
Eur J Neurol. 2022 Sep;29(9):2596-2606. (PMID: 35510782)
Ophthalmic Physiol Opt. 2022 Sep;42(5):1009-1014. (PMID: 35687309)
Arch Ophthalmol. 2001 Jul;119(7):1050-8. (PMID: 11448327)
- Grant Information:
The Norwegian Glaucoma Research Foundation; Arthur and Odd Clauson's Legacy; Oslo University Hospital; The Norwegian Association of the Blind
- Contributed Indexing:
Keywords: drivers licence; driving ability; driving simulator; perimetry; visual field
- Publication Date:
Date Created: 20241021 Date Completed: 20250210 Latest Revision: 20250630
- Publication Date:
20250701
- Accession Number:
PMC11810553
- Accession Number:
10.1111/aos.16783
- Accession Number:
39428625
No Comments.