Comparison Between Patent Ductus Arteriosus Stent and Modified Blalock-Taussig Shunt as Palliation for Infants With Ductal-Dependent Pulmonary Blood Flow

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Publication Information:
      Ovid Technologies (Wolters Kluwer Health), 2018.
    • Publication Date:
      2018
    • Abstract:
      Background: Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking. Methods: Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups. Results: One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P =0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P P =0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8–91.1; P P P P =0.006), and larger (152 mm 2 /m 2 [95% CI, 132–176] versus 125 mm 2 /m 2 [95% CI, 113–138]; P =0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8–0.89] versus 0.77 [95% CI, 0.75–0.8]; P =0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up. Conclusions: In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.
    • ISSN:
      1524-4539
      0009-7322
    • Rights:
      OPEN
    • Accession Number:
      edsair.doi...........f7228d47eac027c51f5d7b8ac797465b