Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Finite element analysis of narrow dental implants

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Contributors:
      Universitat Politècnica de Catalunya. Departament d’Enginyeria Gràfica i de Disseny; Universitat Politècnica de Catalunya. Departament de Física; Universitat Politècnica de Catalunya. Departament de Ciència i Enginyeria de Materials; Universitat Politècnica de Catalunya. InSup - Grup de Recerca en Interacció de Superfícies en Bioenginyeria i Ciència dels Materials
    • Publication Information:
      Elsevier BV, 2020.
    • Publication Date:
      2020
    • Abstract:
      Narrow-diameter implants (NDIs) traditionally have been associated to higher rates of failure in comparison with regular-diameter implants (RDIs) and wide-diameter implants (WDIs), since they generate a more unfavorable stress distribution in peri-implant bone. However, it is well known that the load sharing effect associated with prostheses supported by multiple implants (also called splinted prostheses) affords mechanical benefits. The present study involves finite element analysis (FEA) to determine whether the risks linked to NDIs could be mitigated by the mechanical advantages afforded by the splinting concept. For this purpose, a three-dimensional (3D) model of a real maxilla was reconstructed from computed tomography (CT) images, and different implants (NDIs, RDIs and WDIs) and prostheses were created using computer-aided design (CAD) tools. Biting forces were simulated on the prostheses corresponding to three different rehabilitation solutions: single-implant restoration, three-unit bridge and all-on-four treatment. Stress distribution around the implants was calculated, and overloading in bone was quantified within peri-implant volumes enclosed by cylinders with a diameter 0.1mm greater than that of each implant. The mechanical benefits of the splinting concept were confirmed: the peri-implant overloaded volume around NDIs splinted by means of the three-unit bridge was significantly reduced in comparison with the nonsplinted condition and, most importantly, proved even smaller than that around nonsplinted implants with a larger diameter (RDIs). However, splinted NDIs supporting the all-on-four prosthesis led to the highest risk of overloading found in the study, due to the increase in compressive stress generated around the tilted implant when loading the cantilevered molar.
    • File Description:
      application/pdf
    • ISSN:
      0109-5641
    • Accession Number:
      10.1016/j.dental.2020.04.013
    • Rights:
      Elsevier TDM
      CC BY NC ND
    • Accession Number:
      edsair.doi.dedup.....a767f575186772ca816238dfb70bd251