Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Metal-chelating antioxidant peptides - Biosensor screening methods as alternatives to the ferrozine assay

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Contributors:
      ROSSI, Sabine; Danmarks Tekniske Universitet = Technical University of Denmark (DTU); Laboratoire Réactions et Génie des Procédés (LRGP); Université de Lorraine (UL)-Centre National de la Recherche Scientifique (CNRS); Interactions Arbres-Microorganismes (IAM); Université de Lorraine (UL)-Institut National de Recherche pour l’Agriculture, l’Alimentation et l’Environnement (INRAE); Ingénierie Moléculaire, Cellulaire et Physiopathologie (IMOPA); Ingénierie Moléculaire et Physiopathologie Articulaire (IMoPA); Additionally, the authors want to thank US Company Kalsec as this study has been partially funded by them. Besides, the authors thank the French ministry government for the MESR grant, the ANR JCJC MELISSA (2020-2024), and the project of the 'Lorraine Université d’Excellence' (Investissements d’avenir-ANR project number 15-004).
    • Publication Information:
      Preprint
    • Publication Information:
      Authorea, Inc., 2024.
    • Publication Date:
      2024
    • Abstract:
      Preventing metal-catalyzed lipid oxidation in food products, which decreases nutritional value and sensory quality, is crucial in the food industry. This is typically achieved through the use of metal-chelating molecules. While the ferrozine assay is widely used to screen protein hydrolysates for metal chelating activity, it has proven difficult to use with pure peptides. This study evaluates the potential of Surface Plasmon Resonance (SPR) and Electrically Switchable Nanolever Technology (switchSENSE®) as alternative screening methods. Unfortunately, solubility issues and large standard deviations precluded a direct correlation between the ferrozine assay and these biosensor techniques. Both techniques, however, were able to quantitatively distinguish between two peptides with very similar sequences despite the absence of a correlation between dissociation constants determined by SPR and switchSENSE®. This study highlights the potential of SPR and switchSENSE® for screening the metal chelating activity of pure peptides, advancing the understanding of peptide-metal ion interactions.
    • File Description:
      application/pdf
    • ISSN:
      1558-9331
      0003-021X
    • Accession Number:
      10.22541/au.171223997.71294832/v1
    • Accession Number:
      10.1002/aocs.12834
    • Rights:
      CC BY NC
      CC BY
    • Accession Number:
      edsair.doi.dedup.....fefc9a1a5911d4894420c7b7eb3b142f