Stack-level diagnosis of proton exchange membrane fuel cell by the distribution of relaxation times analysis of electrochemical impedance spectroscopy

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Contributors:
      Zhengzhou University; Franche-Comté Électronique Mécanique, Thermique et Optique - Sciences et Technologies (UMR 6174) (FEMTO-ST); Université de Technologie de Belfort-Montbeliard (UTBM)-Ecole Nationale Supérieure de Mécanique et des Microtechniques (ENSMM)-Centre National de la Recherche Scientifique (CNRS)-Université de Franche-Comté (UFC); Université Bourgogne Franche-Comté COMUE (UBFC)-Université Bourgogne Franche-Comté COMUE (UBFC); Systèmes et Applications des Technologies de l'Information et de l'Energie (SATIE); École normale supérieure - Rennes (ENS Rennes)-Conservatoire National des Arts et Métiers CNAM (CNAM)-Université Paris-Saclay-Centre National de la Recherche Scientifique (CNRS)-Ecole Normale Supérieure Paris-Saclay (ENS Paris Saclay)-Université Gustave Eiffel-CY Cergy Paris Université (CY)
    • Publication Information:
      HAL CCSD
      Elsevier
    • Publication Date:
      2024
    • Collection:
      Université de Franche-Comté (UFC): HAL
    • Abstract:
      International audience ; A comprehensive Distribution of Relaxation Times (DRT) analysis is carried out for a proton exchange membrane fuel cell (PEMFC) in this research, to achieve stack-level fault diagnosis by Electrochemical Impedance Spectroscopy (EIS). The durability and reliability of PEMFC are still crucial challenges for its commercialization, and EIS is a potential characteristic tool for diagnosis. However, the explanation and application of EIS are still ambiguous and insufficiently exploited for the PEMFC stack. DRT is a useful tool for EIS analysis, but it has not been applied to stack-level PEMFC diagnosis yet. In this work, to explore the possibility of using DRT as a PEMFC diagnosis tool, experiments are designed and carried out under different operating conditions, while the current, stoichiometry of the cathode, stoichiometry of the anode, temperature, and relative humidity are adjusted. Further, the detailed method to analyze PEMFC EIS data by DRT is presented, and the relationship between the PEMFC fault and DRT is built according to massive experiments and quantitative analysis. The DRT peaks can be assigned to the corresponding inner processes, and the diagnostic significance of the DRT features is quantitatively compared. Additionally, a novel equivalent circuit model (ECM) structure is proposed according to the DRT analysis, which is composed of 6 resistor-capacitor circuits that correspond to the inside processes, thus significantly contributing to stack-level fault diagnosis.
    • Relation:
      hal-04563354; https://univ-eiffel.hal.science/hal-04563354; https://univ-eiffel.hal.science/hal-04563354/document; https://univ-eiffel.hal.science/hal-04563354/file/Yunjin%20Ao%20et%20al%20-%20JPS%20-%20Mai%202024%20-%20Version%20HAL.pdf
    • Accession Number:
      10.1016/j.jpowsour.2024.234420
    • Online Access:
      https://univ-eiffel.hal.science/hal-04563354
      https://univ-eiffel.hal.science/hal-04563354/document
      https://univ-eiffel.hal.science/hal-04563354/file/Yunjin%20Ao%20et%20al%20-%20JPS%20-%20Mai%202024%20-%20Version%20HAL.pdf
      https://doi.org/10.1016/j.jpowsour.2024.234420
    • Rights:
      info:eu-repo/semantics/OpenAccess
    • Accession Number:
      edsbas.AA4BFDDD