Item request has been placed! ×
Item request cannot be made. ×
loading  Processing Request

Impact of systolic blood pressure limits on the diagnostic value of triage algorithms

Item request has been placed! ×
Item request cannot be made. ×
loading   Processing Request
  • Additional Information
    • Publication Information:
      BioMed Central
    • Publication Date:
      2017
    • Collection:
      Dresden University of Technology: Qucosa
    • Abstract:
      Background Major incidents are characterized by a lack of resources compared to an overwhelming number of casualties, requiring a prioritization of medical treatment. Triage algorithms are an essential tool for prioritizing the urgency of treatment for patients, but the evidence to support one over another is very limited. We determined the influence of blood pressure limits on the diagnostic value of triage algorithms, considering if pulse should be palpated centrally or peripherally. Methods We used a database representing 500 consecutive HEMS patients. Each patient was allocated a triage category (T1/red, T2/yellow, T3/green) by a group of experienced doctors in disaster medicine, independent of any algorithm. mSTaRT, ASAV, Field Triage Score (FTS), Care Flight (CF), “Model Bavaria” and two Norwegian algorithms (Nor and TAS), all containing the question “Pulse palpable?”, were translated into Excel commands, calculating the triage category for each patient automatically. We used 5 blood pressure limits ranging from 130 to 60 mmHg to determine palpable pulse. The resulting triage categories were analyzed with respect to sensitivity, specificity and Youden Index (J) separately for trauma and non-trauma patients, and for all patients combined. Results For the entire population of patients within all triage algorithms the Youden Index (J) was highest for T1 (J between 0,14 and 0,62). Combining trauma and non-trauma patients, the highest J was obtained by ASAV (J = 0,62 at 60 mmHg). ASAV scored the highest within trauma patients (J = 0,87 at 60 mmHg), whereas Model Bavaria (J = 0,54 at 80 mmHg) reached highest amongst non-trauma patients. FTS performed worst for all patients (J = 0,14 at 60 mmHg), showing a lower score for trauma patients (J = 0,0 at 60 mmHg). Change of blood pressure limits resulted in different diagnostic values of all algorithms. Discussion We demonstrate that differing blood pressure limits have a remarkable impact on diagnostic values of triage algorithms. Further research is needed to ...
    • Relation:
      https://tud.qucosa.de/id/qucosa%3A30689
    • Online Access:
      https://nbn-resolving.org/urn:nbn:de:bsz:14-qucosa-231546
      https://tud.qucosa.de/id/qucosa%3A30689
      https://tud.qucosa.de/api/qucosa%3A30689/attachment/ATT-0/
    • Rights:
      info:eu-repo/semantics/openAccess
    • Accession Number:
      edsbas.D7E05444