Abstract: The author’s purpose was to compare 2 different osteosynthesis with LCP plate paired either with 6 bicortical locking screws or 6 bicortical standard screws, used to repair comminuted tibial fractures. The 2 different constructs were applied on 12 ovine tibial pairs. Bone-plate constructs and contralateral bones were loaded in quasi-static torsion, with the extrinsic angular stiffness measured, in order to determine the influence of screw locking. Extrinsic angular stiffness was higher in the locking group, but this difference was not statistically significant. No implant failure was observed within maximal torque of 7 N.m. ; Dans le cadre du traitement des fractures diaphysaires comminutives du tibia, via l’utilisation de plaques LCP, l’auteur se propose de comparer deux types de montages, le premier constitué de 6 vis bicorticales verrouillées et le second constitué de 6 vis bicorticales standard. L’étude a été réalisée sur 12 paires de tibias ovins. Les os appareillés (tibias gauches) et les os controlatéraux (tibias droits) ont été soumis à des tests quasi-statiques en torsion. La raideur angulaire extrinsèque a été mesurée, afin de déterminer l’influence du verrouillage des vis sur le comportement mécanique des divers montages. Les résultats ont mis en évidence une moyenne des raideurs angulaires extrinsèques supérieure pour les montages verrouillés par rapport aux montages standard, mais la différence entre les deux modes de fixation s’avère non statistiquement significative. Ces mêmes résultats ont montré l’absence de rupture des montages en torsion avec un couple maximal de 7 N.m.