Item request has been placed!
×
Item request cannot be made.
×

ETT Rotation During Nasal Fiberoptic Intubation
Item request has been placed!
×
Item request cannot be made.
×

- Source:Effect of 90° Degree Counterclockwise Rotation of the Endotracheal Tube on Its Advancement Through the Larynx During Nasal Fiberoptic Intubation in Children: A Randomized and Blinded Study
Johnson DM, From AM, Smith RB, From RP, Maktabi MA. Endoscopic study of mechanisms of failure of endotracheal tube advancement into the trachea during awake fiberoptic orotracheal intubation. Anesthesiology. 2005 May;102(5):910-4. doi: 10.1097/00000542-200505000-00008.
Maktabi MA, Hoffman H, Funk G, From RP. Laryngeal trauma during awake fiberoptic intubation. Anesth Analg. 2002 Oct;95(4):1112-4, table of contents. doi: 10.1097/00000539-200210000-00061.
Ovassapian A, Yelich SJ, Dykes MH, Brunner EE. Fiberoptic nasotracheal intubation--incidence and causes of failure. Anesth Analg. 1983 Jul;62(7):692-5. No abstract available.
Brull SJ, Wiklund R, Ferris C, Connelly NR, Ehrenwerth J, Silverman DG. Facilitation of fiberoptic orotracheal intubation with a flexible tracheal tube. Anesth Analg. 1994 Apr;78(4):746-8. doi: 10.1213/00000539-199404000-00022.
Randell T, Hakala P, Kytta J, Kinnunen J. The relevance of clinical and radiological measurements in predicting difficulties in fibreoptic orotracheal intubation in adults. Anaesthesia. 1998 Dec;53(12):1144-7. doi: 10.1046/j.1365-2044.1998.00612.x.
Hakala P, Randell T. Comparison between two fibrescopes with different diameter insertion cords for fibreoptic intubation. Anaesthesia. 1995 Aug;50(8):735-7. doi: 10.1111/j.1365-2044.1995.tb06108.x.
Asai T, Shingu K. Difficulty in advancing a tracheal tube over a fibreoptic bronchoscope: incidence, causes and solutions. Br J Anaesth. 2004 Jun;92(6):870-81. doi: 10.1093/bja/aeh136. Epub 2004 Apr 30. No abstract available.
Kristensen MS, Moller J. Airway management behaviour, experience and knowledge among Danish anaesthesiologists--room for improvement. Acta Anaesthesiol Scand. 2001 Oct;45(9):1181-5. doi: 10.1034/j.1399-6576.2001.450921.x.
Schwartz D, Johnson C, Roberts J. A maneuver to facilitate flexible fiberoptic intubation. Anesthesiology. 1989 Sep;71(3):470-1. doi: 10.1097/00000542-198909000-00038. No abstract available.
Aoyama K, Takenaka I. Markedly displaced arytenoid cartilage during fiberoptic orotracheal intubation. Anesthesiology. 2006 Feb;104(2):378-9; author reply 379-80. doi: 10.1097/00000542-200602000-00032. No abstract available.
No Comments.